TB282 Rev2 β Jog Panel Communication Fault
The most common cause of this error is that the control is configured to utilize an optional Jog
Panel/Pendant connection but the Jog Panel/Pendant is not plugged in If the optional Jog
Panel/Pendant will not be installed change the βJog Panel Requiredβ to βNoβ to disable Power
off the system and restart If the optional Jog Panel/Pendant was ordered confirm that it is
plugged at both the MPU11/ALLIN1DC and on backside the jogpanel board itself on the header
labeled βCPU10β
1 If the system is not utilizing a Jog Panel/Pendant Go into the Control Configuration
Screen and change βJog Panel Requiredβ to Noβ To enter the βControl Configuration Screenβ
from the Main Screen press
F1 Setup >F3 Config pw=137 enter >F1 Control
Use the arrow keys to select βJog Panel Requiredβ and press the spacebar to toggle the setting
to βNoβ Power off and restart the control after changing this setting
2 Did the LED's on the Jog Panel/Pendant flash on power up? If the LED's did not flash
immediately on power up check the back of the jog board and confirm that the data cable is
correctly plugged into the header labeled CPU10 If this cable is plugged in correctly and the
LED's did not flash on power up it is likely that the Jog Panel/Pendant will need to be returned
for repair Please contact your dealer to arrange repair replacement or further troubleshooting
3 Does your Jogboard have the updated crystal installed?
4 Does your MPU11 have the updated crystal installed? MPU11 boards that shipped prior
to 7/31/14 may need to have the crystal replaced due to a manufacturing defect in the crystal