Content Preview
TB256 Rev2 Yaskawa VS 606V7 Inverter Setup
Setup parameters on Yaskawa Inverter
Objective
The purpose of this document is to provide the information needed to correctly setup the Yaskawa inverter
for a Centroid CNC control
Yaskawa VS 606V7 Inverter Settings
Parameter No Value Units Description
n001 1 read and set
n001 n049
8 2 wire
initialization
Password parameter
selection / initialization
n002 0 V/f control Control mode selection
n003 1 control circuit
terminal
Run command selection
n004 2 control circuit
terminal 0 10v
Select frequency
reference
n005 0 decel to stop Stopping method
selection
n011 Must be set with
tach to match max
spindle speed
Hz Maximum Output
Frequency
n019 3 sec Acceleration Time
n020 1 5 depending
upon braking
resistor
sec Deceleration Time
n036 Depends on motor A Motor current
All other
parameters
are set to factory default
Wiring connections
L1 L2 L3 3 phase power in
S1 Forward run
S2 Reverse run
S4 Fault reset
SC Input common
FR Master speed frequency reference 0 10vdc
FC Frequency reference common
MA Fault output normally open
MC Fault output common
U/T1 V/T2 W/T3 Motor voltage out
B1 B2 Braking resistor
_________
Document History
Rev2 Created on 2012 01 09 by #358
Rev1 Created on 2012 01 09 by #358